Relative humidity transmitters
with voltage output 0-10V

photo of transmitter HG421.65

Humidity transmitter HG010.65

Air relative humidity transducers with voltage output 0-10V are available in wall-mount, duct-mount and bar types. Transmitter contains a microprocessor based control circuitry in a durable plastic case with a connection terminal and a humidity sensor in a bronze sintered filter. Computerized design ensures maximum long term stability, temperature compensation of the humidity sensor and fail indication. State-of-the-art capacitive polymer sensor ensures excellent calibration long term stability, inertia against water and condensation. Transmitters are designed for use in non-aggressive environment.

APPLICATIONS - measuring and control of air relative humidity at:

COMMON TECHNICAL PARAMETERS
Relative humidity measuring range: 0 to 100%
Accuracy: ±2.5% relative humidity from 5 to 95% at 23°C
Voltage output of relative humidity: 0-10V linearly corresponds 0% -100% relative humidity,
Operational range of case with electronics: -30 to +80°C
Range of temperature compensation of humidity sensor: -30 to +105°C
Filtering ability of sintered bronze sensor cover: 0.025mm
Protection of the case with electronics: IP65
Power: 15-30Vdc, maximum consumption 25mA
Warranty: two years

Transducers are available in the following types:

Type Operating temperature range Length Note Manual in pdf format

HG010.65

Larger image
-30 to +80°C 67mm outdoor, dimensions

HG010.65-150

Larger photo
-30 to +105°C* 150mm duct mount, dimensions Manual in pdf

HG010.65-700

Larger photo
-30 to +105°C* 700mm bar type, dimensions Manual in pdf

* 105°C only at the end of measuring tip with the limitation accordingly to the Working range graph. Near plastic case with electronics and terminals maximum temperature is +80°C.

Working range of humidity sensor

Figure: Working range of humidity sensor

Included accessory:

Included is a calibration certificate from the manufacturer - Comet, plastic gland for direct mounting of the bar and duct type transmitters to a 29mm diameter hole.

OPTIONAL ACCESSORY
Larger photo F0000 spare sintered bronze sensor cover with thread for measuring of temperature and humidity of polluted air. Filtering ability of the cover is 0.025mm.
Larger photo F5100 plastic sensor cover with thread for measuring of temperature and humidity of clean indoor spaces.
Larger photo PP4 flat plastic circular flange for duct mounting
Larger photo PP90 right-angled stain-less steel flange for wall mounting
Image accessory for calibration and adjustment of humidity by the user
Interconnection terminals

Figure: Interconnection terminals
terminal UDD
power voltage positive pole (typically +24Vdc)
terminal UOUT voltage output positive pole
terminal GND ground, power voltage negative pole, output voltage negative pole