Relative humidity and temperature transmitters with RS485 or RS232 serial output

photo of transmitter NH485, respective NH232

Humidity transmitter HG010.65

Computerized design ensures maximum long term stability, temperature compensation of the humidity sensor and fail indication. Measured quantities are converted to digital serial output with the RS485 or RS232 link parameters. Communication protocol is Advantech standard ADAM compatible. Measured values can be in Engineering units or floating decimal point format (IEEE754). It is possible to read the transducer configuration, its type, firmware version, modify the communication parameters including activation of CRC and transducer calibration. Sensor breakage or short circuit is indicated. RS485 transducers have the address space available at the range of 0-255.
State-of-the-art capacitive polymer sensor excels in mechanical stress, temperature shock, dew resistance as well as in large linearity range and low hysteresis. Air humidity transducers are designed for use in non-aggressive environment.

APPLICATIONS - measuring and control of air relative humidity at:

COMMON TECHNICAL PARAMETERS
Temperature sensor: RTD Ni1000-6180ppm/°C
Measuring temperature range: -30 to +80°C
models NH485-150,NH485-700: -30 to +105°C at the end of the tube with sensors
Accuracy: ±0.4°C at the range of -30 to +80°C
Measuring air relative humidity range: 0 to 100%
Accuracy: ±2.5% RH at the range of 5 to 95% at 23°C
Range of temperature compensation of the humidity sensor: -30 to +105°C
Power: 9 to 30 V DC, current consumption approx. 8mA
Protection of the case with electronics and terminals: IP65
Filtering ability of sintered bronze sensor cover: 0.025mm
Communication protocol
for temperature transmitters:
compatible with the Advantech standard ADAM
Communication protocol
for humidity and temperature transmitters:
compatible with the Advantech standard ADAM
Communication speed: 1200,2400,4800,9600,19200 Bd
Warranty: two years

Transducers are available in the following types:

TRANSMITTERS WITH RS232 SERIAL OUTPUT
- galvanic NOT ISOLATED from power circuitry
Type Measured value Operating temperature range Length Note Manual in pdf format

N232

Larger photo
T -30 to +80°C 45mm outdoor and indoor, terminals, dimensions Manual in pdf format

NH232

Larger photo
T+RH -30 to +80°C 67mm outdoor and indoor, terminals, dimensions Manual in pdf format
TRANSMITTERS WITH RS485 SERIAL OUTPUT
- galvanic ISOLATED from power circuitry
Type Measured value Operating temperature range Length Note Manual in pdf format

N485

Larger photo
T -30 to +80°C 45mm outdoor and indoor, terminals, dimensions Manual in pdf format

NH485

Larger photo
T+RH -30 to +80°C 67mm outdoor and indoor, terminals, dimensions Manual in pdf format

NH485-150

Larger photo
T+RH -30 to +105°C* 150mm duct mount,
terminals
, dimensions
Manual in pdf format

* 105°C only at the end of measuring tip with the limitation accordingly to the Working range graph. Near plastic case with electronics and terminals maximum temperature is +80°C.

Working range of humidity sensor

Figure: Working range of humidity sensor

Included accessory:

Included is a calibration certificate from the manufacturer and instruction manual with the complete communication protocol description.
Transmitters with the RS232 output have included 2 meter cable for communication with RS232 computer port.

OPTIONAL ACCESSORY
Larger photo F0000 spare sintered bronze sensor cover with thread for measuring of temperature and humidity of polluted air. Filtering ability of the cover is 0.025mm.
Larger photo F5100 plastic sensor cover with thread for measuring of temperature and humidity of clean indoor spaces.
Larger photo PP4 flat plastic circular flange for duct mounting
Larger photo PP90 right-angled stain-less steel flange for wall mounting
Image accessory for calibration and adjustment of humidity by the user

Transmitters are directly compatible with sixteen channel Comet monitoring systems MS2+, MS3+, MS4+.