Monitoring systems MS2+, MS3+, MS4+

Single-channel to sixteen-channel dataloggers are designed for recording of values from transducers of variety of quantities, alarm state indication, and process control. Parameters of inputs are defined by the types of installed input modules. Datalogger with transducers configured accordingly to client order can measure analog signals, frequency, count impulses, evaluate two-state quantities and read data from devices compatible with ADAM Advantech protocol. If input signal modification is required it is possible to modify the input modules for different types. Input signals are connected to removable terminal block located on the logger upper side. Analyzing of the record is enabled after data download to the personal computer by means of the included program.

The complete solution for monitoring of temperature, humidity and other values especially in following applications:

New generation especially enables:

 

Monitoring system MS2+:

Larger photo

no display, no alarm function, only for measurement and record

Monitoring system MS3+:

Larger photo

all functions as MS2+, in addition dual line alphanumeric LCD display and four push buttons. LCD enables to display actual values from input channels and datalogger configuration. Two limits for each channel are adjustable for alarm function. Out of range values are indicated by appropriate LED and audio signal. The direction of the limits, hysteresis and audio indication are user programmable for each channel. Each MS3+ datalogger has ALARM OUT output e.g. for connection of external audio alarm indication or a voice dialer. PC program enables to set wide variety of alarm modes. From simple (increase/decrease of measured value referring to set limit) to complex (logic combination up to 4 conditions from different input channels, additional time functions etc.)

 

Monitoring and control system MS4+:

Larger photo

all functions as MS3+ plus installed board with 16 output relays (250V/8A) with switchitching-over contacts for controlling of external devices. Each relay can be switched by appearance of one or more alarms at different input channels accordingly to setting from the PC program. Contacts of the relays can control external devices (switching OFF the device, switching ON the heating or ventilation, switching ON of distant alarm etc.). Output signals from relays and the power are connected to internal terminals via cable glands.

STANDARD FEATURES OF AVAILABLE MODELS OF MONITORING SYSTEM MS2+ MS3+ MS4+
record of data YES YES YES
dual line LCD display and four buttons on the front panel YES YES
alarm indication - audible and visible on the datalogger panel YES YES
output for external alarm indication YES YES
built-in communication interface RS485, operation of several dataloggers in the network YES YES
16 output relays YES
TECHNICAL PARAMETERS
Memory type: internal SRAM, backed-up by Lithium battery
Total memory capacity: 2MB (up to 480 000 values)
Logging mode: noncyclic - logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Logging interval: adjustable from 1 second to 24 hours, common for all channels
Real time clock: year, leap year, month, day, hour, minute, second, backed-up by Lithium battery
Input measured values (1 to 16 inputs): are defined for each channel by installed input modules (see table) accordingly to user requirements
Resolution of the AD converter (analog channels): 16 bits, conversion duration approximately 100ms/channel
Interface for communication with computer: RS232 (RxD,TxD,RTS,CTS,GND) - direct connection with computer up to 15 meters, connection with computer by telephone modem, GSM modem, USB converter, Ethernet converter
RS485 (only for MS3+, MS4+) - connection with computer up to 1200 m, possibility of connection of several dataloggers to one communication link
Supported communication speeds: 1200, 9600, 19200, 57600, 115200 Bd
Output for alarm indication (only MS3+, MS4+): voltage signal 0V/4.8V, maximum current 50mA, output is designed for connection of external audio indication or telephone dialer
Relay alarm outputs (only MS4+): 16 relays (max. 8A/250Vac), switching-over contacts
Power: from external ac/dc adapter, included in delivery (supplying from source 24V DC possible)
Operating temperature range of datalogger: 0 to 50°C
Dimensions, weight - MS2+, MS3+: 230 x 180 x 90 mm (W x L x D), weight approximately 800g
Dimensions, weight MS4+ (MS2+,MS3+ for thermocouples): 250 x 320 x 110 mm (W x L x D), weight approximately 2000g
Protection: IP20, optional watertight case IP55 (only MS2+, MS3+)
Warranty: two years
TYPES OF INPUTS
Type Measured value Accuracy Note
A0 dc current 4 to 20 mA ±0.1% FS With source approximately 21V for two-wire transducers with current loop (e.g. temperature and humidity transducers Comet). Only galvanic not isolated.
A1* dc current 4 to 20 mA ±0.1% FS for passive sensing of current
B0* dc current 0 to 20mA ±0.1% FS  
B1* dc current 0 to 1A ±0.1% FS  
B2* dc current 0 to 5A ±0.1% FS  
C0 ac current 0 to 20mA ±1% FS galvanic isolated
C1 ac current 0 to 1A ±1% FS galvanic isolated
C2 ac current 0 to 5A ±1% FS galvanic isolated
D0* dc voltage 0 to 100mV ±0.1% FS  
D1* dc voltage 0 to 1V ±0.1% FS  
D2* dc voltage 0 to 10V ±0.1% FS  
D3* dc voltage 0 to 400V ±0.1% FS  
E0 ac voltage 0 to 100mV ±1% FS galvanic isolated
E1 ac voltage 0 to 1V ±1% FS galvanic isolated
E2 ac voltage 0 to 10V ±1% FS galvanic isolated
E3 ac voltage 0 to 400V ±1% FS galvanic isolated
F* measurement of resistance (specify the range) ±0.1% FS two-wire connection
J* input for Nickel RTD temperature sensor Ni1000, 6180 ppm/°C, range -50 to +250°C -50 to 100°C ±0.2°C 100 to 250°C ±0.2% from reading  
K* input for Platinum RTD temperature sensor Pt100, range -140 to +600°C -140 to+100°C ±0.2°C 100 to 600°C ±0.2% from reading two-wire connection
K1* input for Platinum RTD temperature sensor Pt1000, range -140 to +600°C -140 to+100°C ±0.2°C 100 to 600°C ±0.2% from reading two-wire connection
N* thermocouple K (NiCr-Ni) range -70 to +1300°C ±(0.3% + 1°C) from reading linearized, cold junction compensation
T* thermocouple T (Cu-CuNi) range -200 to +400°C ±(0.3% + 1°C) from reading linearized, cold junction compensation
O* thermocouple J (Fe-Co) range -200 to 750°C ±(0.3% + 1°C) from reading linearized, cold junction compensation
P* thermocouple S (Pt10%Rh-Pt), range 0 to 1700°C ±(0.3% + 1°C) from reading from +200 to +1700°C linearized, cold junction compensation
Q* thermocouple B (Pt30%Rh-Pt), range +100 to +1800°C ±(0.3% + 1°C) from reading from +300 to +1800°C linearized
S* binary input for potential-less contacts maximum resistance of closed contact: 1000 ohms minimum duration for recording: 200ms
S1 binary voltage input voltage for "switched ON" state: 3 to 30Vdc, input current in the"switched ON" state: 1 to 9mA-depending on the applied voltage, minimum duration for indication of change: 200ms, galvanic isolated
CTU counter input for voltage signal voltage for "HIGH" state (for counter status change): 3 to 24Vdc maximum pulse frequency 5kHz, backed-up operation, galvanic isolated
CTK counter input for potential-less contacts and open collector maximum pulse frequency 5kHz, programmable filter of pulse ringing, backed-up operation during power mains failure, maximum resistance of closed contact: 10 kohms minimum resistance of open contact: 250 kohms, galvanic unisolated
FU input for measurement of frequency of voltage signal 0 to 5kHz, resolution 1Hz, accuracy ±(0.2% from reading + 1Hz) input voltage for state "H": 3 to 24Vdc input current in state "H": approximately 7mA minimum duration of input impuls: 30us, galvanic isolated
FK input for measurement of frequency of contact switching 0 to 5kHz, resolution 1Hz, accuracy ±(0.2% from reading + 1Hz) maximum resistance of closed contact: 10 kohms minimum resistance of open contact: 250 kohms, minimum duration of input pulse: 30us, galvanic unisolated
RS input for serial signal RS485 for devices supporting Advantech protocol e.g. measurement from transmitters with RS485 digital output connected to the serial RS485 network - ADAM Advantech protocol , galvanic isolated

Input module A0 4 to 20mA

Counter input module CTU

Larger image

Opened MS3+ with 14 installed input modules

Notes: Inputs marked ( * ) are not galvanic isolated and have common ground. These inputs are available also as galvanic isolated. Galvanic isolated analog inputs are marked with letter G following the name of input type (e.g. input for passive measurement of current 4-20mA - type A1 - with galvanic isolation is marked A1G). Galvanic isolation is not designed as safety protection. Datalogger for thermocouple measurement has always larger case. Input RS always maps all channels from its position to position 16. Therefore input RS should always be installed to the position with the highest input channel number.

Included accessories:

Calibration certificate from the manufacturer - Comet, ac/dc adapter, wall holders, communication cable for RS232 of 2 meters length, free program for Windows. Free program is available to dowload anytime. Program enables to control all logger functions and view and print the record in numerical format.

OPTIONAL ACCESSORY
Image SWR003 optional software for Windows - comfort graphic environment, including on-line graph
Larger image Watertight unit in larger case with cable glands with protection rate IP55 - only for MS2+, MS3+. Not available for loggers with thermocouple inputs and MS4+.
Case dimensions 250 x 320 x 110 mm.
Larger photo MP006 external RS232/USB converter for communication with the PC via USB port
M2006 built-in interface for communication with the PC via USB port
- only for new MS3+, MS4+ with full memory 2MB
M2007 built-in interface for communication with the PC via Ethernet network
- only for new MS3+, MS4+ with full memory 2MB
Larger photo MP001 external RS485/RS232 converter for serial port COMx of the PC, ac/dc adapter included
- only for MS3+, MS4+
Larger photo M2002 external audio indication unit
- only for MS3+, MS4+
MP002 telephone voice dialer for alarm reporting, ac/dc adapter included
- only for MS3+, MS4+
Image humidity transmitters humidity and temperature transmitters with 4-20mA output
Image temperature transmitters temperature transducers with 4-20mA output
Image
Image
probes temperature probes with Pt1000/3850ppm sensor without connector - probe marking is followed by symbol /0
Image probes thermocouple temperature probes "K" NiCr-Ni

Manual in pdfBasic part of the Instruction Manual for MS2+, MS3+, MS4+ monitoring system in pdf format

Manual in pdfAppendixes to basic part of the Instruction Manual for MS2+, MS3+, MS4+ monitoring system in pdf format

MONITORING SYSTEM UPGRADE - Older generation of loggers MS2, MS3, MS4 produced after 1998 (serial numbers beginning from 99, 00, 01, 02, 03) can be upgraded to new generation MS2+, MS3+, MS4+ at authorized partners.

Manual in pdfInstruction Manual for older generation of MS2, MS3, MS4 loggers in pdf format