Main applications:
- Food and beverage industry (HACCP)
- Pharmaceutical industry
- Horticulture and cultivation of plants
- HVAC (heating, ventilation, air conditioning, cooling)
- Building and energy management
- Research and development
- Laboratories (GLP)
- Warehouses
- Technological processes
- Museums, archives, galleries
Advantages:
- included calibration certificate from the manufacturer - Comet
- fast data transfer to the PC (full memory for approximately 30s)
- variability of connection to the computer - USB, RS232, Ethernet
- permanent connection to the PC enabled, data is possible to download even during logging
- large data memory 32000 values
- large dual line display with special symbols, switchable
- optional display of minimum and maximum measured values (reset of min/max memory from PC or by magnet)
- dual level alarm is enabled for each channel, alarm is indicated by blinking of the value on the LCD display or LED diode
- two alarm modes are enabled: instant or with memory (detected alarm is indicated permanently till alarm memory is cleared from the PC)
- robust watertight case
- easy installation, locking enabled
- low power consumption from battery, battery life up to 7 years
- indication of remaining battery life, easy replacement of the battery
- it is possible to combine temperature and RH measurement with two user calibrated 0-5V voltage signals
- logging start/stop is enabled in several ways: at certain time and date programmed from computer, by delivered magnet
- also special logging mode is enabled, when logging runs only, if some of measured values are out of adjusted alarm limits
- each logger is possible to describe with text of maximum 32 characters
- each channel is possible to describe with text of maximum 16 characters
- password protection is enabled to prevent unauthorized manipulation with logger
| COMMON TECHNICAL PARAMETERS | |
|---|---|
| Operating temperature range of loggers R3120, R3121 without display: | -30 to +80°C |
| Operating temperature range of loggers S3xxx with display: | -30 to +70°C |
| Accuracy of temperature measurement of internal sensor: | ±0.4°C |
| Accuracy of the S3631 logger Pt1000 input without probe: |
±0.2°C from -50 do +100°C ±0.2% from reading from +100 to +260°C ±0.4% from reading from -90 to -50°C |
| Accuracy of air humidity measurement: | ±2.5% RH from 5 to 95% at 23°C |
| Accuracy of dew point measurement: | ±0.5°C from 30 to 95% RH |
| Resolution of the reading: | 0.1°C, 0.1%RH |
| Real time clock: | year, leap year, month, day, hour, minute, second |
| Logging interval: | adjustable from 10s to 24h (1minute to 24h in low-power mode) |
| Display and alarm refresh: | each 10 s (each 1 minute in low-power mode) |
| Total memory capacity: | 32000values in noncyclic logging mode |
| Logging modes: |
noncyclic - logging stops after filling the memory cyclic - after filling memory oldest data is overwritten by new |
| Dimensions without connectors: |
loggers with display 93x64x29mm loggers without display 93x64x26mm |
| Power: | Lithium battery 3,6V, size AA |
| Typical battery life in low-power mode (1minute sampling): |
7 years R3120, R3121 6 years S3120, S3121, S3631, S3541 |
| Typical battery life in fast mode (10 second sampling): |
3 years R3120, R3121 2.5 years S3120, S3121, S3631, S3541 |
| Battery life in continuous on-line mode with interval 1 minute: | reduced to 70% of the above lives in fast mode |
| Battery life in continuous on-line mode with interval 10 second: | 1 year |
| Warranty: | 2 years |
| LOGGERS WITH LCD DISPLAY | ||||
|---|---|---|---|---|
| Type | Measured signals | Measuring range | Manual in pdf format | |
|
S3120 - thermometer-hygrometer including dew point temperature with internal T+RH sensors | T+RH |
temperature -30 to +70°C humidity 0 to 100% |
|
|
S3121 - thermometer-hygrometer including dew point temperature with external T+RH probe with cable length of 1 meter. Cable lengths 2 and 4 meters available optionally. Probe diameter is 18mm, length 75mm. | T+RH |
temperature -30 to +105°C* humidity 0 to 100% |
|
|
S3631 - thermometer-hygrometer with internal T+RH sensors. Additional connector for external temperature probe. Alternative display of dew-point temperature, external probe temperature and the temperature difference of external probe and dew-point temperature. Necessary to order external temperature probe with Pt1000 sensor with female K1321 connector. | T+RH +Text |
internal -30 to +70°C external -90 to +260°C humidity 0 to 100% |
|
|
S3541 - thermometer-hygrometer including dew-point calculation with internal T+RH sensors. Additional Canon 9pins connector for two signals 0-5Vdc (±0.2% FS accuracy). Necessary to order connector for connection of input signals. | T+RH + 2x0-5V |
internal -30 to +70°C humidity 0 to 100% |
|
Common manual for quick start of all Sxxxx, Rxxxx loggers
Temperature operating range of loggers S3121, R3121
Thermometer R0110
with wall holder
Accessories
Calibration certificate from the manufacturer - Comet and battery are included in delivery. For basic use it is necessary to order at minimum a COM adapter or USB adapter for communication with computer, optionally a start/stop magnet, if needed to control logging the other way than directly from computer.
Anytime it is possible to download free basic program for Windows. Program enables to control all logger functions and viewing and printing of record in numerical and simple graphic format. It is possible to export logged values to dbf or txt formats for further analysis.
| OPTIONAL ACCESSORIES | ||
|---|---|---|
|
SWR001 | optional software for Windows - color printing, vertical and horizontal zooming of graphs and other functions. |
|
SW100 | CD with free PC program |
|
LP002 | COM adapter for communication with personal computer via RS232 serial port |
|
LP003 | USB adapter for communication with personal computer via USB port |
|
LP005 |
LAN adapter - external converter for communication with the PC via Ethernet, including ac/dc adapter 230Vac/5Vdc, 350mA
More information in manual in pdf format |
|
LP004 | start/stop magnet |
|
MD036 | self adhesive Dual Lock for easy installation |
|
F9000 | wall holder secured against unauthorized removal |
|
A4203 | spare Lithium battery 3.6V size AA |
|
K1321 | spare female connector for connection of S3631 logger temperature probe, protection IP67 |
|
K0921 | watertight female connector Canon 9 pins for connection of 0-5V signals of S3541 logger, protection IP67. |
|
K0925 | female connector Canon 9 pins for connection of 0-5V signals of S3541 logger, protection IP20. |
|
K0945 | adapter with terminals for easy connection of 0-5V signals of S3541, protection IP20. |
|
F2000 | sensor cover from sintered bronze for thermo-hygrometers R3120, S3120, S3631, S3541, filtering ability of 0.025mm |
|
F0000 | sensor cover from sintered bronze for thermo-hygrometers S3121, R3121 - filtering ability of 0.025mm |
|
PP4 | flat circular flange - for mounting of external probe of loggers S3121, R3121 |
|
PP90 | right-angled stain-less steel flange for mounting of external probe of loggers S3121, R3121 |
|
accessory for calibration and adjustment of humidity by the user | |